LIVE US GRID TELEMETRY: 50 States & PR
πŸ‡ΊπŸ‡Έ National Grid Power Outage Incident SCADA Live
Oncor Electric Delivery
Coyanosa, TX β€’ Pecos County β€’ ZIP 79730

Coyanosa, TX 79730 (Pecos County) Power Outage

Official Oncor Electric Delivery Field Crew Dispatch & Restoration Bulletin (#35055) • Public Utility Commission of Texas Jurisdiction

Dispatch: 1-888-313-4747
Estimated Time of Restoration (ETR) Official Telemetry
06:00 PM Target Time
Nov 23, 2026 (Target Date)
Started: Nov 23, 03:54 PM β€’ Duration: 2.1h β€’ Load: 1
⚑ Feeder & Substation Telemetry Circuit #91
Distribution Voltage
13.2 kV / 120V
Breaker Tripping
Auto-Isolated
Grid Footprint: PUCT ● SCADA Synced
Time Remaining Until Estimated Restoration Live Clock
00
Hours
:
00
Minutes
:
00
Seconds
πŸ‘· Lineworker Crew & Triage Phase Confidence: 94%
● Field Unit: Bucket Truck & Cable Splicing Active

Field crews are working to safely isolate downed conductors and restore feeder circuits. Stay at least 35 feet back from all power lines.

Incident Classification: emergency NERC Monitored
Field Crew Protocol

Grid Restoration Progress & Timeline

Phase 2/5
βœ“ Logged
Telemetry Alert
2 En Route
Crew En Route
3 Pending
Feeder Repairs
4 Pending
Substation Test
5 Target ETR
Grid Restored
Live Perimeter & Regional Grid Surveillance

Affected Area: Coyanosa (79730)

Primary Incident Regional Alert Surrounding Normal
πŸ“ 30.7120Β° N, -102.6768Β° W
πŸ—³οΈ

Is Power Still Down for You?

Community Status Radar β€’ Coyanosa

20 Votes

Experiencing service disruption at your address in Coyanosa? Cast your 1-click status vote:

● Out: 70% ● Surging: 20% ● Restored: 10%
Call Dispatch
Community Discussion

Resident Reports & Field Updates

Verified neighborhood crowdsource updates from residents in Pecos(ZIP 79730).

Moderated Community Feed β€’ Verified Civic Grid

Verified Resident Reports (0)

Live Signal
πŸ“‘
No resident reports logged yet for this specific sector.

Be the first neighbor on your block to confirm current power or broadband status above!

Alert Neighbors & Share

Regional Grid Surveillance

Grid Status Across Neighboring Counties in Texas

Adjacent utility districts connected to the same state transmission footprint.

View Entire Texas Grid Map →
πŸ“ Pecos County Active Outage
Pop: 1,000
Affected: 1
Current Monitoring Target
Sabine County Grid Stable
Pop: 8,500 100% Operational
Inspect Sabine Grid →
Rains County Grid Stable
Pop: 8,500 100% Operational
Inspect Rains Grid →
Hood County Grid Stable
Pop: 8,500 100% Operational
Inspect Hood Grid →
Hopkins County Grid Stable
Pop: 8,500 100% Operational
Inspect Hopkins Grid →
Motley County Grid Stable
Pop: 8,500 100% Operational
Inspect Motley Grid →
Hale County Grid Stable
Pop: 8,500 100% Operational
Inspect Hale Grid →
Grid Telemetry & Feeder Corridors

Coyanosa, TX Affected Areas & Feeder Network

Compiled directly from Oncor Electric Delivery real-time outage management system (OMS).

City / County
Coyanosa / Pecos
US ZIP Code
79730
Impacted Meters
1 accounts
Classification
emergency

Affected Subdivisions, Avenues & Feeder Circuits

Pecos County Distribution Grid (TX)
Incident Root Cause
Live Kubra Telemetry: 1 active distribution circuit event(s) reported by Oncor Electric Delivery
State Public Utility Commission (PUC)

Sustained Outage Bill Credit & Food Spoilage Compensation

Under state utility service standards, residential customers experiencing unscheduled power outages exceeding 4 to 8 consecutive hours may qualify for utility billing credits ($25 - $250) or food loss claim reimbursements from Oncor Electric Delivery.

Calculate Bill Credit Claim β†’

πŸ›‘οΈ Safety Protocols & Checklist

β–Ά Downed Conductor & Ground Gradient Hazards

Surviving fatal step-potential voltages near fallen utility poles:

  • Maintain 35-Foot Minimum Distance: Electricity can arc through wet soil and chain-link fences.
  • Never Touch Entangled Vehicles: If a wire falls across your car, stay inside until lineworkers confirm line de-energization.
  • Shuffling Foot Motion: If forced to move away, keep feet closely together and shuffle without lifting boots.

β–Ά State PUC Tariffs & Outage Billing Reimbursements

Enforcing utility reliability standards under Texas administrative rules:

  • Consecutive Interruption Credits: Regulated utilities must credit accounts for outages extending beyond statutory limits.
  • Preserve Outage Incident Record: Keep incident #35055 telemetry logged here for formal billing appeals.
  • State Consumer Advocate: File tariff complaints through your state public utility commission.

β–Ά Main Panel & Double-Pole Breaker Triage

Confirm whether this blackout is isolated to your residence or utility-wide in Coyanosa:

  • Inspect Neighboring Structures: If adjacent homes have streetlights and porch lamps lit, check your main 200A breaker.
  • Double-Pole Reset Protocol: Firmly switch the main breaker fully OFF before throwing it back to ON.
  • Observe Neighborhood Grid Status: Flickering lights or street interruptions often indicate distribution switches or lightning arrestor operations.
Technical Infrastructure Dossier β€’ OutageUSA Observatory

Pecos County, TX Grid Engineering Analysis & Event Audit

Comprehensive technical examination of transmission, distribution, and consumer rights.

I. Distribution System Dynamics & Smart Meter Telemetry in Pecos County, TX

Electrical service delivery across Pecos County, Texas (ZIP Code 79730) is governed by modern Advanced Metering Infrastructure (AMI) connected to Oncor Electric Delivery's distribution management system under oversight of the Public Utility Commission of Texas and Electric Reliability Council of Texas (ERCOT). Smart meters continuously transmit radio-frequency health beacons over a 900 MHz mesh network, reporting voltage anomalies, phase loss, and momentary blinks.

The disruption indexed under incident reference #35055 currently affects an estimated 1 customersβ€”representing approximately 0.5% of the energized circuits in Pecos County. Dispatch records link the fault to: Live Kubra Telemetry: 1 active distribution circuit event(s) reported by Oncor Electric Delivery. When physical conductors fault, smart meters emit a high-priority 'Last Gasp' transmission using onboard capacitor reserve power, immediately geo-locating the outage perimeter without requiring manual customer phone calls.

AMI Mesh Network Diagnostics: Carrier control software analyzes meter telemetry clusters to isolate the exact distribution line fuse or transformer cutout that operated, shortening field patrol durations across Pecos County.

Oncor Electric Delivery emergency field lineworkers deployed to repair grid fault in Coyanosa, Texas
High-Voltage Linework Dispatch:

Emergency bucket truck lineworkers deployed to clear downed overhead conductors and restore primary feeder loop serving Coyanosa, Texas (ZIP 79730).

II. High-Voltage Physical Line Restoration Protocols

Restoring high-voltage electrical distribution circuits across Pecos County requires meticulous adherence to OSHA 1910.269 high-voltage safety standards:

  1. Visual De-Energization & Grounding: Lineworkers attach portable grounding clusters to isolated conductors to create an equipotential zone, protecting mechanics from accidental line re-energization or induced backfeed.
  2. Fiberglass Hotstick Line Work: Lineworkers use insulated hotsticks to disconnect damaged transformer taps, test line voltage, and hook mechanical line tensioners.
  3. Transformer Phase Balance Verification: Field technicians measure transformer secondary voltages to ensure split-phase 120/240V balance prior to closing neighborhood cutouts.
  4. System Frequency & Voltage Normalization: Operators verify that distribution feeder bus voltage remains within ANSI C84.1 Range A (114V to 126V nominal) to prevent home appliance damage.
SCADA network telemetry and automated grid monitoring for Oncor Electric Delivery outage incident #35055
SCADA Telemetry & Feeder Radar:

Centralized SCADA telemetry terminal monitoring automated vacuum recloser trip sequences and bus voltages across Oncor Electric Delivery's Texas service footprint.

III. Consumer Advocacy & Regulatory Protections in Texas

The Public Utility Commission of Texas (PUCT) serves as the official consumer regulatory body overseeing investor-owned and municipal utilities across Texas. Administrative guidelines mandate that utilities provide timely public outage notifications, maintain emergency dispatch centers, and minimize average customer interruption durations.

Residents in Pecos County can utilize OutageUSA incident verification #35055 when filing billing inquiries or formal complaints regarding persistent power quality issues, recurring transformer failures, or prolonged repair intervals with the PUCT Consumer Services Division.

IV. Emergency Generator Operation & Carbon Monoxide Safeguards

Operating emergency backup generators during this blackout requires life-safety vigilance: portable generators produce lethal concentrations of colorless, odorless carbon monoxide (CO). Never run a combustion engine inside a garage, basement, or enclosed porchβ€”even with doors open. Keep generator exhaust oriented downwind at least 20 feet from all structure openings. Ensure an approved double-throw transfer switch is utilized to avoid deadly electrical backfeed into utility lines.

⚑ Other Active Outages in Texas

View All State Outages β†’

❓ Frequently Asked Questions

Official guidance for Coyanosa residents during this incident.

When will power or service be restored in Coyanosa (79730)?

According to Oncor Electric Delivery dispatch telemetry, estimated restoration is currently Nov 23, 2026 at 6:00 PM EST. Field crews and mutual assistance line mechanics are actively isolating distribution circuit faults and sectionalizing feeder loops.

Who is the utility company responsible for this incident in Pecos?

This infrastructure sector is operated by Oncor Electric Delivery. You can contact emergency dispatch directly at 1-888-313-4747 or verify localized telemetry via their online portal.

Can I claim statutory outage credits through PUCT in Texas?

Under administrative tariffs enforced by the Public Utility Commission of Texas (PUCT), utility customers experiencing prolonged non-storm interruptions beyond statutory duration thresholds may qualify for prorated billing credits. File your claim directly with Oncor Electric Delivery citing incident #35055.

What regional grid and weather threats impact Pecos?

Across Texas, utility infrastructure is challenged by Summer heat-dome peaker turbine stress and winter freeze-in valve icing. Grid reliability standards coordinated through Electric Reliability Council of Texas (ERCOT) require ERCOT Ancillary Services dispatch and weatherization inspections under Texas Senate Bill 3 to prevent cascading blackouts.

How do I report a downed power line or public hazard in Pecos?

Always treat downed electrical lines as fully energized and lethal. Maintain a minimum 35-foot perimeter and dial 911 immediately. Never attempt to remove entangled tree limbs from conductors yourself.